Before water

Inspect support, fitting insertion, crimp gauges, clamp position, thread engagement, valve direction and component ratings. Air tests can be hazardous and are not permitted for every plastic system; use only a manufacturer-approved method and pressure.

Water test

Fill partially, confirm vent/overflow, prime pump, open one fixture at a time, purge air and close all outlets. Observe shutoff and whether the pump restarts with no demand.

Hot and drains

Heat water under supervision, check relief/mixing behavior and every hot joint. Fill sinks/pan then release quickly to challenge drains, traps, vents and grey inlet.

Road retest

Inspect after the first fill, full hot cycle, overnight pressure hold, first drive and first rough-road trip. Mark baseline pump cycle and tank-level behavior.

Build rule

If you cannot reach it, isolate it, drain it and explain its pressure/temperature or water-quality job, it is not ready to hide behind a wall.

CHAPTER CHECK

• I can explain the purpose and failure mode of each item in this chapter. • I know which manufacturer limit or water-quality claim controls my choice. • I added the valve, access, drain, measurement or maintenance task to my drawing/checklist.