Energy and runtime
At about 0.8 kW while the compressor runs, 4 compressor-hours use roughly 3.2 kWh; 8 hours approach 6.4kWh before fan/other loads and any cycling difference. Measure actual Wh, not just elapsed time.
Usable battery
A 10 kWh nominal bank does not mean 12.5 guaranteed hours. Reserve, battery limits, voltage, temperature,other loads and conversion/wiring losses reduce practical runtime.
Solar mismatch
Our 750 W roof array may yield roughly 2-3 kWh on a good day depending on season/weather. It cannot reliablyreplace a heavy 6 kWh cooling day plus living loads.
Recovery sources
Alternator charging around 50 A, shore and load management close the gap. Cooling independence is anenergy-balance problem: stored energy only delays the moment generation must catch up.
Compressor time
A/C energy at ~0.8 kW
Meaning
2 h
~1.6 kWh
short pre-cool/afternoon
4 h
~3.2 kWh
large share of daily bank
8 h
~6.4 kWh
solar cannot reliably replace alone
12 h
~9.6 kWh
near nominal 10 kWh before other loads
CHAPTER CHECK
• I can explain which heat path this step addresses.• I measured its effect at front, middle and rear - not only by touch.• I added its power, failure mode, maintenance and safety action to the system plan.